MIL-PRF-81/6F
REQUIREMENTS:
Capacitance value: See table I.
DC rated voltage: See table I.
Operating temperature and storage range: -55°C to +125°C.
Characteristics: See table I.
Dielectric withstanding voltage:
Method 301 of MIL-STD-202:
A dc potential of 200 V dc applied between terminals for 3 seconds ±2 seconds.
TABLE I. Style CV35 and CV36.
Characteristic
Type
Capacitance
DC
designation
(pF)
rated
Capacitance change from value at 25°C
voltage
Symbol
(volts)
At -55°C
At +85°C
At +125°C
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
percent
percent
percent
percent
percent
percent
CV35A030
1.0
3.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV36A030
1.25
3.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
2.0
5.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV3-A050 2/
2.5
9.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV3-A090
3.5
20.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV3-A200
5.0
15.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV3-A150 2/
5.0
25.0
100
A
-4.5
+2.0
-2.5
+2.0
-4.2
+3.4
CV3-A250
7.0
40.0
100
C
-1.0
+6.5
-4.0
-1.0
-6.7
-1.7
CV3-C400
CV3-G400
7.0
40.0
25
G
-0.0
+14.0
-8.0
-3.0
-14.0
-5.0
1/ Where applicable, the complete type designation will include an additional digit to indicate CV35 or CV36.
2/ Characteristic F is hereby canceled and there is no superseding part.
Barometric pressure (reduced): Method 105 of MIL-STD-202, condition D (100,000 feet). Test potential: 100
percent of dc rated voltage.
Insulation resistance: Method 302 of MIL-STD-202, condition A, 100 volts dc applied: 10,000 megohms,
minimum.
Capacitance: Method 305 of MIL-STD-202.
DF: At 1 MHz ±100 kHz, at maximum and minimum capacitance: Shall be not more than 0.2 percent for
characteristic A and 0.5 percent for characteristics C and G.
Temperature coefficient: Within the limits specified for the applicable characteristic.
3