Vibration, high frequency: Method 204 of MIL-STD-202, condition B (15 g's).
Capacitance change: Shall not exceed ±2 percent or 0.5 pF, whichever is greater.
DF: Shall be not more than 0.2 percent.
Dielectric withstanding voltage: 500 V dc, applied for 3 seconds ±2 seconds.
Insulation resistance: Shall be 10,000 megohms, minimum.
Fatigue:
C: Shall not exceed 12 percent or 0.75 pF, whichever is greater.
Torque: Initial requirement.
Life:
Qualification test: 1,000 hours at +85°C, 150 percent of rated V dc applied.
Insulation resistance: Initial requirement.
Capacitance change: Shall not exceed ±8 percent of initial value or 0.5 pF, whichever is greater.
Group C life: Conditions and requirements are the same as that for qualification except that capacitance change
shall not exceed ±5 percent of initial value or 0.5 pF, whichever is greater.
Moisture resistance: Method 106 of MIL-STD-202.
Insulation resistance: Shall be 10,000 megohms minimum.
Capacitance change: Shall not exceed ±5 percent of nominal value or 0.5 pF, whichever is greater.
DF: Shall be not more than 0.5 percent.
Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the
extent of the changes.
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - EC
Air Force - 11
(Project 5910-2010-07)
DLA - CC
Review activities:
Air Force - 19, 99
3