MIL-PRF-55365/2E
Stability at low and high temperatures: In accordance with MIL-PRF-55365.
Step 1 (+25°C):
DCL -
See table I.
Cap. -
Shall not exceed tolerance of table I value.
DF -
See table I.
ĆCap. -
Step 2 (-55°C):
Shall not exceed ±10 percent of initial measurement.
DF -
See table I.
Step 3 (+25°C):
DCL -
See table I.
ĆCap. -
Shall not exceed ±5 percent of initial +25°C measurement.
DF -
See table I.
Step 4 (+85°C):
DCL -
See table I.
ĆCap. -
Shall not exceed ±10 percent of initial +25°C measurement.
DF -
See table I.
Step 5 (+125°C): DCL -
See table I.
ĆCap. -
Shall not exceed ±15 percent of initial +25°C measurement.
DF -
See table I.
Step 6 (+25°C):
DCL -
See table I.
ĆCap. -
Shall not exceed ±5 percent of initial +25°C measurement.
DF -
See table I.
Surge voltage: In accordance with MIL-PRF-55365.
DCL - See table I.
ĆCap. - Within ±5 percent of initial value.
DF
- See table I.
Life: Method 108 of MIL-STD-202.
2,000 hours:
At 25°C:
DCL - See table I.
ĆCap. - Shall not exceed ±5 percent of initial measured value.
DF - See table I.
At 85°C:
DCL - See table I.
At 125°C:
DCL - See table I.
10,000 hours:
At 25°C:
DCL - See table I.
ĆCap. - Shall not exceed ±10 percent of initial measured value.
DF - See table I.
At 85°C:
DCL - 200 percent of initial requirement.
At 125°C:
DCL - 200 percent of initial requirement.
3