MIL-PRF-49137/2D
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Case material:
Dipped, epoxy or plastic.
Leads: Solder-coated metal.
DC rated voltage: See table I.
Operating temperature: -55C to +85C.
DC leakage (DCL): See table I.
Capacitance (cap.): See table I.
Cap. tolerance: 10% (K), or 20% (M).
Dissipation factor (DF): See table I.
Stability at low and high temperature: In accordance with MIL-PRF-49137.
Step 1 (+25):
See table I.
DCL
-
Cap.
-
Within tolerance specified in table I.
See table I.
DF
-
Step 2 (-55C):
Cap. -
Within -15 percent of step 1 measured value.
DF
-
200 percent of table I.
Step 3 (+25C):
See table I.
DCL
-
Cap. -
Within 10 percent of step 1 measured value.
DF
-
See table I.
Step 4 (+85C):
10 times 25C limit (see table I).
DCL
-
Cap. -
Within +15 percent of step 1 measured value.
150 percent of table I.
DF
-
Step 5 (+25C):
DCL
-
See table I.
Cap. -
Within 10 percent of step 1 measured value.
See table I.
DF
-
Surge voltage: In accordance with MIL-PRF-49137.
- See table I.
DCL
Cap. - Within 10 percent of initial value.
DF
- See table I.
Life: Method 108 of MIL-STD-202.
1,000 hours:
At 25C:
DCL
- 200 percent of table I.
Cap. - Within 10 percent of initial measured value.
- See table I.
DF