MIL-PRF-39014/21B
TABLE II.
Capacitance change with reference to 25°C
Capacitance change
Dissipation
After life
After immersion,
Steps E through G
Steps A through D
factor (max)
moisture resistance,
of table VI of
of table VI of
and resistance to
soldering heat
Bias = Rated voltage
Bias = 0 volts
±2%
±5%
+2, -10%
+2, -10%
1.0%
±2%
±10%
+2, -15%
+2, -15%
1.5%
±5%
±20%
+20, -45%
+20, -50%
3.0%
*
NOTES:
Reference document. MIL-PRF-39014.
*
Changes from previous issue. The margins of this specification are marked with asterisks to indicate where
changes from the previous issue were made. This was done as a convenience only and the Government assumes no
liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the
requirements of this document based on the entire content irrespective of the marginal notations and relationship to
the last previous issue.
Custodians:
Preparing activity:
Air Force - 11
DLA - CC
DLA - CC
(Project 5910-2006-063)
Review activities:
Air Force - 99
*
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities change, you should verify the currency of the information above using the ASSIST
Online database at https://assist.daps.dla.mil/ .
6