MIL-PRF-39006/25E
Insulation resistance (IR): Method 302 of MIL-STD-202, condition B. 100 megohms, minimum.
Low temperature (storage): Method 502 of MIL-STD-810.
DCL: See table I.
ĆCap: Within ±5 percent of initial measurement.
DF: See table I.
Stability at low and high temperatures:
Step 1 (+25°C):
DCL: See table I.
ĆCap: Within tolerance of table I value.
DF: See table I.
Step 2 (-55°C):
Impedance. See table I.
ĆCap: See table I.
Step 3 (+25°C):
DCL: See table I.
ĆCap: Within ±5 percent of step 1 value.
DF: See table I.
Step 4 (+85°C):
DCL: See table I.
ĆCap: See table I.
DF: See table I.
Step 5 (+125°C):
DCL: See table I.
ĆCap: See table I.
DF: See table I.
Step 6 (+25°C):
DCL: See table I.
8