MIL-C-62/8E
Surge voltage: In accordance with MIL-C-62.
DCL: See table I.
Capacitance change: 6 percent.
DF: See table I.
Vent: Not applicable.
Life: Method 108 of MIL-STD-202, test condition F.
DCL: See table I.
Capacitance change: 100 volts, dc rated, and less: -20, + 15 percent.
DC rated voltage above 100 volts: ± 15 percent.
DF: Meet the initial requirement or not exceed 150 percent of the initial measurement.
Barometric pressure: Method 105 of MIL-STD-202.
Shelf life: In accordance with MIL-C-62.
Build factor: Not more than 4.0.
Shelf factor: Not more than 3.0.
DCL: Not more than 150 percent of initial value.
Capacitance change: 6 percent.
DF: Not more than 175 percent of initial requirement.
Application data:
All capacitors shall withstand an rms ripple current at 120 Hz and 85ºC as determined from the formula:
Ir = k C
Where:
Ir = rms ripple current in milliamps.
C = normal capacitance in microfarads.
k = 50 for units rated at 15 and 300 volts dc.
= 40 for units rated at 350 to 450 volts dc, inclusive.
Supersession data: See table II.
QUALIFICATION ASSURANCE PROVISIONS:
Qualification inspection: Not applicable.
Retention of qualification: Not applicable.
Conformance inspection: Group A inspection only.
8