MIL-C-62/7D
Moisture resistance: Method 106 of MIL-STD-202.
Insulation resistance (insulating sleeve): Not less than 100 megohms.
DWV: Insulating sleeves - Method 301 of MIL-STD-202. 4,000 volts dc applied.
DCL: Not more than 150 percent of initial requirement.
DC: See table I.
Corrosion: Not more than 10 percent.
Stability at low and high temperature: In accordance with MIL-C-62.
Step 1 (at + 25șC).
DCL: See table I.
Capacitance: See table I.
DF: See table I.
Step 2 (at -40șC): Impedance - See table I.
Step 3 (at +25șC):
DCL: See table I.
Capacitance: ± 5 percent of initial value.
DF: See table I.
Step 4 (at +85șC):
DCL: Not more than 10 times initial value, or meet initial 25șC requirement.
Capacitance - ± 20 percent of initial value.
DF: See table I.
Step 5 (at +25șC):
DCL: See table I.
Capacitance - ± 5 percent of initial value.
DF: See table I.
Surge voltage: In accordance with MIL-C-62.
DCL: See table I.
Capacitance change: 6 percent.
DF: See table I.
5