MIL-C-62/3D
Dissipation factor: See table I.
Terminal strength: Method 211 of MIL-STD-202, test conditions A, B, and E.
Shock (specified pulse): Method 213 of MIL-STD-202, test condition I.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B.
Salt atmosphere (corrosion): Method 101 of MIL-STD-202, test condition B.
Temperature cycling and immersion:
Thermal shock: Method 107 of MIL-STD-202, test condition A.
Immersion: Method 104 of MIL-STD-202, test condition C.
DWV (insulating sleeves): Method 301 of MIL-STD-202. 4,000 volts dc applied.
DCL: Not more than 150 percent of initial measurement.
Capacitance change: 5 percent.
DF: See table I.
Corrosion: Not more than 10 percent.
Moisture resistance: Method 106 of MIL-STD-202.
Insulation resistance (insulating sleeve): Not less than 100 megohms.
DWV (insulating sleeves): Method 301 of MIL-STD-202. 4,000 volts dc applied.
DCL: Not more than 150 percent of initial requirement.
Capacitance change: 5 percent.
DF: See table I.
Corrosion: Not more than 10 percent.
Stability at low and high temperature: In accordance with MIL-C-62.
Step 1 (at +25°C):
DCL: See table I.
Capacitance: See table I.
DF: See table I.
Step 2 (at -40°C):
Impedance: See table I.
Step 3 (at +25°C):
7