MIL-C-62/12G
Surge voltage: In accordance with MIL-C-62.
DCL: See table I.
Capacitance change: 6 percent.
DF: See table I.
Vent: In accordance with MIL-C-62.
Life: Method 108 of MIL-STD-202, test condition F.
DCL: See table I.
Capacitance change: 100 volts, dc rated, and less: - 20, + 15 percent.
DC rated voltage above 100 volts: 15 percent.
DF: Meet the initial requirement or not exceed 150 percent of the initial measured value whichever is greater.
Barometric pressure: Method 105 of MIL-STD-202.
Shelf life: In accordance with MIL-C-62.
Build factor: Not more than 4.0 (see basic).
Shelf factor: Not more than 3.0 (see basic).
DCL: Not more than 150 percent of initial requirement.
Capacitance change: 6 percent.
DF: Not more than 175 percent of initial requirement.
VERIFICATION:
Qualification inspection: Not applicable.
Retention of qualification: Not applicable.
Conformance inspection: Group A inspection only.