MIL-C-62/11E
Impedance: See table I.
Step 3 (at +25°C):
DCL: See table I.
Capacitance change: ±5 percent of Initial value.
DF: See table I.
Step 4 (at +85°C):
Capacitance change: 20 percent of initial value.
DF: See table I.
Step 5 (at +25°C):
DCL: See table I.
Capacitance change: ±5 percent of initial value.
DF: See table I.
Surge voltage: In accordance with MIL-C-62.
DCL: See table I.
Capacitance change: 6 percent.
DF: See table I.
Vent: Not applicable.
Life: Method 108 of MIL-STD-202, test condition F.
DCL: See table I.
Capacitance change: 100 volts dc rated and less: -20, +15 percent.
DC rated voltage above 100 volts: ±15 percent.
DF: Meet the initial requirement or not exceed 150 percent of the initial measurement, whichever is greater.
Barometric pressure: Method 105 of MIL-STD-202.
Shelf life: In accordance with MIL-C-62.
Build factor: Not more than 4.0.
Shelf factor: Not more than 3. 0.
DCL: Not more than 150 percent of initial requirement.
Capacitance change: 6 percent.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business